Troubleshooting
During each step, test for voltage (220 Volts) between each respective supply terminal and the common
terminal on the supply terminal board. Terminal 14 is the common terminal for the pumps.
The supply terminal board should be wired as shown in Figure 2.
Figure 2
CFS8N
Pump
1
Pump
2
Pump
3
Pump
4
Pump
5
Pump
6
Supply
Relay
1
12
Supply
Relay
2
34
Supply
Relay
3
56
Supply
Relay
4
78 910
Supply
Relay
5
Supply
Relay
6
11 12
13* 14**
ELECTRICAL CONNECTION OF THE LIQUID SUPPLY PUMPS
* L1 (110 VAC) wire or terminal for remote liquid supply connection.
** L2 common wire (110 VAC) or terminal for remote liquid supply connection.